Technician preparing aluminium window drawings for a project schedule

A door and window schedule lists the sizes, materials, glazing, hardware and performance requirements for each opening. For multi-unit projects, clear and consistent information helps manufacturers prepare accurate quotations and avoid production errors.

This guide covers the key schedule fields, dimension references, performance ratings, quantity records and document revisions that project teams should check before placing an order.

What a Door and Window Schedule Actually Does

The schedule converts a design intent into a buildable instruction, and a quotation is only ever priced off the instruction.

A drawing set answers geography. A plan locates the opening, an elevation shows the wall, a large-scale detail shows the reveal and the sealant line. None of those sheets tells a plant how many millimeters of profile to extrude or which glass to order.

The schedule carries that load. One row per window type. The row states a reference code, a size with a declared basis, a material and a glazing make-up. It adds a finish, a hardware set, a swing or direction, a performance rating, and a count. A shop drawing then returns the same row as a drawing the site can approve.

A schedule written to serve a drawing set lists what a drafter needs to draw. A factory version has a harder test. Could a stranger, in another country, with no phone call and no site visit, buy the right aluminum, gaskets, glass and hardware from this row alone?

Our own intake page asks for exactly this document. We tell project teams to send architectural drawings, window and door schedules, opening sizes, product requirements or reference images, and we price from what arrives.

When a row cannot answer the stranger test, the gap gets filled by guesswork somewhere down the line. That is where the phrase “as per schedule” does real damage: every reader supplies the missing detail from their own side of the transaction.

The Columns a Factory Needs to Quote From

Interior door sizes shown as height, width and thickness references

A column earns its place by fixing a buying decision; anything else costs you a clarification round later.

The table below is the set we work from on custom aluminum doors and windows. The third column is our own practice, stated as ours: what goes wrong on our side of the transaction when the value is missing from a row.

Column What the value must fix What happens when it is missing
Reference code One identifier every later document can reuse Every later document invents its own name
Type and instance count How many frames to build and how many rooms to fit Order quantity becomes an argument on site
Size with a stated basis Profile cutting lengths and glass ordering sizes We guess which of three dimensions you meant
Material and alloy Which die, which stock, which thermal break Substitution happens at the extrusion, silently
Glazing make-up Pane thickness, cavity, coating, gas, edge seal Tempered and Low-E become two different units
Finish system Pre-treatment, coating type, color standard, gloss A color name matches two powder codes
Hardware set Handles, locks, hinges, strikers, load per leaf Frame prep is cut for the wrong package
Swing and orientation Which jamb carries the hinge, which hand opens Left-hand units arrive for right-hand rooms
Performance values Test program, class and grade, size tested The label cannot be produced at the tested size

Columns That Change the Price

Four of those columns decide cost directly. Glazing make-up sets glass cost and can decide whether the frame needs a deeper cavity. Hardware set changes both the package price and the machining. Finish system decides whether the unit goes through anodizing or powder coating, which are two different processes. The performance values decide whether an existing test report covers the row or a new program is needed.

Material belongs in that group too, even though it reads as background detail. Our product pages state the alloy and temper outright, for example a 6063-T5 native aluminum profile, because the temper and the wall build change what a die can produce.

Columns You Can Drop

Drop a decorative name column when the reference code already does the work. Drop a separate hardware style column when a hardware schedule is issued as its own document, and cross-reference it instead. Avoid vague color names such as “charcoal.” Specify a RAL color code or another agreed color reference, along with the required coating system and performance specification, such as AAMA 2605 where applicable.

Keep the manufacturer column only when it records a genuine project constraint, such as a proprietary system that the project is committed to using. If the frame is manufactured to your specified section details, naming a manufacturer in this column adds little value.

Which Dimension the Size Column Actually Lists

Door size diagram comparing two, three and four panel widths

The same 36-by-80 unit produces three legitimate numbers, and a factory that guesses wrong builds the wrong object.

A schedule size can mean any of three dimensions, and the number itself does not say which one. A structural opening is the hole in the building. A frame size is the manufactured unit. A rough opening is the framed space the unit is set into, larger than the frame by an installation allowance.

Our own framing guidance shows how far apart those numbers run. For a 36-by-80 inch door, it advises adding about 2 inches to the width and 2 to 2.5 inches to the height. That yields an estimated rough opening of about 38 by 82 to 82.5 inches. It also states a consistent gap of 1/4 inch to 1/2 inch on each side between the jamb and the jack studs, to leave room for plumbing and squaring.

Read together, those lines say the allowance is not a constant. It moves with the door and frame specification, and with the shim space available on site. That is why the same guide tells installers to work from the manufacturer’s stated frame and rough-opening dimensions, not a rule of thumb.

The Same Number Three Meanings

A row listing 38 by 82.5 can be a framed space the builder already built or a unit nobody can manufacture. A row listing 36 by 80 can be the frame or the structural hole it fills. A quotation built on the wrong reading does not announce itself. The units ship, the opening is right, and the frame arrives two inches too wide to drop in.

The failure is silent because both numbers are plausible. Nothing in the drawing set contradicts a row whose number is the framed space rather than the frame. The contradiction appears with a shim pack and a level on site.

Name the Basis Once and Never Again

Put one sentence at the top of the schedule: sizes are stated as frame dimensions, or as structural openings, or as rough openings. Then hold that basis across every row, including the rows you copied from a previous project.

Two bases end up inside one schedule when rows are copied forward, a tower sheet carrying a detail from an older drawing. A reviewer catches the mix by checking one row against its own plan dimension, not by reading all of them.

Performance Columns a Label Can Prove

A PG number alone proves nothing; class, tested size and the underlying test values carry the proof.

North American fenestration products carry a performance designation for a reason. The NAFS primary designator is defined as a three- or four-part code covering performance class, performance grade, the maximum size tested to achieve that rating, and optionally the product type.

The same document prints the format a label must follow. A casement example reads: Class R – PG25: Size tested 760 × 1520 mm (~30 × 60 in). The class letters are not decoration. That standard also states a Performance Grade is achieved only on successful completion of all applicable tests, so the grade is a bundle of results, not a single number.

The gateway table in the same excerpt shows how the pieces sit together. Each class carries a published minimum design pressure and a published minimum water penetration resistance test pressure.

Performance class Minimum design pressure Minimum water test pressure
R 720 Pa (15.04 psf) 140 Pa (2.92 psf)
LC 1,200 Pa (25.06 psf) 180 Pa (3.76 psf)
CW 1,440 Pa (30.08 psf) 220 Pa (4.59 psf)
AW 1,920 Pa (40.10 psf) 390 Pa (8.15 psf)

The published minimums climb together class by class. Performance belongs on the row as class and grade, because a row that states only “tempered, Low-E” cannot be tested against anything.

Size Tested Bounds the Rating

The rating travels up to the tested size and no further. A row asking for a unit larger than the specimen behind its class and grade is not asking for the same product, even when the profile series matches.

This is why the schedule needs a maximum unit size column checked against the tested size, rather than a PG value dropped into a cell. We give the same advice on our hurricane impact window ratings guide. Ask for the approval document that names the tested size range, because certified values travel with the whole assembly.

What NAFS-26 Changes on the Label

The 2026 edition of the standard changes what a schedule may ask for. Metal Construction News reports that the secondary designator became mandatory in NAFS-26, having previously been optional, and must appear in product test reports and labels.

It must show three values: positive design pressure, negative design pressure, and water penetration resistance test pressure. The same report notes the purpose: more detailed performance information on the label, giving clearer reading during submittals, inspections and on-site verification.

For a schedule, the practical effect is that the three columns are no longer a nicety. If the label must carry them, ask the row for them, and ask for them per type rather than per project.

Send Us Your Door and Window Schedule

We quote from your rows, return shop drawings per type under your reference codes, and give technical recommendations where a row is still open.

Direct manufacturer since 2013  |  60,000+ m² plant  |  CAD and shop drawing support

Upload Your Schedule →

OPUOMEN door and window units racked in the factory with protective film on the profiles

Which Document Wins When Two Disagree

A value earns contractual weight by sitting on the governing document, not by being agreed in an email.

Federal contract practice states the ladder plainly. The precedence rule sits in the 48 CFR 552.236-21 supplement to the drawings clause, and the same clause lets large-scale drawings govern where they differ from small-scale ones. A schedule on a drawing outranks the notes around it: “Schedules on any contract drawing shall take precedence over conflicting information on that or any other contract drawing.”

Two consequences follow for anyone issuing a schedule. First, a schedule printed on a drawing sheet outranks conflicting notes elsewhere in the set, so the numbers you care about belong on that sheet. Second, the ladder runs drawings to drawings, not correspondence to drawings.

A change agreed by email does not travel that ladder. It has to be pushed onto a re-issued sheet with a revision marker, or it will not exist at the moment that matters. Our own logistics guide describes the same discipline from the delivery side: receiving checks that components match the Window/Door Schedule in the permit documents.

Changes That Never Reach a Sheet

A value corrected late, verbally, for one type only does not reach the approved row. Nobody re-issues the schedule, so the approved document keeps the old number and the plant builds to the approved document. When the corrected dimension is needed downstream, the row is proof against it.

We ask for re-issued pages rather than confirmations. A revised sheet with a revision triangle is a short job for a drafter, and it settles an argument that otherwise costs a container.

Counting Types Instead of Instances

A factory quotes types, an installer walks instances, and a tally that mixes the two orders the wrong number of frames.

Type count and instance count answer different questions. Types decide how many cutting lists, dies, glass orders and hardware packages get made. Instances decide how many openings a crew finishes and how many units land on which floor.

Building information tools expose the same split. Autodesk’s Revit help describes the schedule option Itemize every instance as displaying all instances in individual rows. Clearing it collapses multiple instances into the same row, by the chosen sorting parameter.

A schedule can list one row per window type or one row per individual opening. For factory quotations, group identical units by type and show the total quantity. Keep a separate instance list when installation teams need opening-by-opening details.

The Quantity Column Needs Two Numbers

A set count alone may not provide enough information for production planning. Record the type quantity, opening quantity, and total area for each window type. These figures help the factory check material requirements and prepare an accurate quotation. A row reading “14 sets” cannot be verified against the floor plan without dimensions, especially in a mixed-CAD tower where window sizes differ across floors.

Including all three figures in each row gives the factory the information needed for material estimates, production planning, and pricing without relying on assumptions.

Turning the Approved Schedule Into a Purchase Order

Commercial project facade with aluminium doors scheduled for order

Each purchase order line should match the approved schedule, including the reference code, quantity, area, dimension basis, material, finish, glazing, hardware and performance requirements.

Use the same reference code across quotations, shop drawings, approvals and packing labels. Avoid renaming units or using informal descriptions.

Add a revision block showing the issue date, revision number and changes. This helps both parties follow the correct version. OPUOMENDW also provides CAD drawings, shop drawings and section details for project coordination.

Frequently Asked Questions

What is a window schedule in construction?

It is a table in the drawing set listing every window type with its size, material, glazing, finish, hardware and performance. Drawings show where openings sit; the schedule states what fills them. Quotations, orders and labels are built from its rows, which makes it the document a factory actually prices.

Should the schedule list rough opening or frame size?

Either one is workable; an undeclared basis is not. State the convention once at the top of the schedule and hold it on every row, including types inherited from older drawings. Frame size is what gets built, rough opening is what gets framed, and the gap between them is an installation allowance that moves with the door and frame specification.

Can a window schedule be used to get a factory quotation?

Yes, when the rows pass a simple test: could a supplier in another country buy the right profile, glass and hardware from the row alone, with no call? Add the dimension basis, the type count, the area per type and the performance values. A quotation from a thin schedule is priced on assumptions you never approved.

Who prepares the window schedule, the architect or the supplier?

The design team issues it inside the contract documents. The supplier returns shop drawings against those rows, and any change goes back onto a re-issued sheet rather than staying in correspondence. We can build the first draft from your drawings, but the version that governs stays a design-side document.

Is a window schedule the same as a bill of quantities?

No. A schedule fixes what each unit is; a bill of quantities prices the same rows for a tender. One is a technical document, the other a commercial one. That difference is why a quotation request written from a schedule should carry the schedule’s own reference codes, not new ones.

What happens when the schedule and the drawings disagree?

Ask which document governs before anybody orders. Federal contract language gives schedules on a contract drawing precedence over conflicting information on that or any other drawing, and lets large-scale details govern over small ones. Email agreements sit outside that ladder until they reach a re-issued sheet.

Yuan Wen

As the Founder and CEO of a premier aluminum window and door manufacturer, I bring over 12 years of specialized expertise in high-performance building materials. My career is defined by a commitment to energy efficiency and engineering excellence, helping contractors and developers worldwide achieve their architectural visions.

Under my leadership, we have successfully exported customized solutions to 30+ countries across Europe, the Middle East, and Southeast Asia, supporting over 500 large-scale residential and commercial projects. I specialize in OEM/ODM manufacturing and complex aluminum-clad wood systems, ensuring every product meets rigorous global standards and diverse climate requirements. I am dedicated to bridging the gap between advanced manufacturing and global trade, providing professional, tailored support for your next project.

Get in Touch

Popular Blogs

It seems we can't find what you're looking for.

Get Your Custom Aluminum Door & Window Quote Today!

Whether you’re looking for high-quality doors, windows, or custom solutions, we’re here to help you bring your vision to life.

*We respect your confidentiality and all information are protected.